Back to product Download PDF
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet

IEEE Std 45/1580 Cable

600V TT(OBS)PMBS Offshore Signal Cable(With Overall Braid Shield)--Pair Twisted

Cable Type 600V Flame retardant:     TP (OBS)PN TP(OBS)PNA TP(OBS)PNB TP(OBS)PNBS     TP(OBS)LSEL TP(OBS)LSELA...

ISO9001 Supplier Class Certificate Export Supply
600V TT(OBS)PMBS Offshore Signal Cable(With Overall Braid Shield)--Pair Twisted

Key Highlights

Category
IEEE Std 45/1580 Cable
Standard
DIN
Material
Tinned Copper/XLPE Insulation/ Neoprene/ Bronze or Tinned Copper Wire/ N...
Weight / Size
245(1995) IEEE 1202(1991) IEC 60332-3 Category A CSA C 22.2 NO.38(at -40...
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.

Technical Specifications

Category
IEEE Std 45/1580 Cable
Model / SKU
600V-TT-OBS-PMBS-Offshore-Signal-Cable-With-Overall-Braid-Shield-Pair-Twisted
Standard
DIN
Material
Tinned Copper/XLPE Insulation/ Neoprene/ Bronze or Tinned Copper Wire/ Neoprene
Weight / Size
245(1995) IEEE 1202(1991) IEC 60332-3 Category A CSA C 22.2 NO.38(at -40℃) IEC 60331-1(FS type Cable) NEK 606   Cores & Size   Cores:
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
Warranty
12 Months unless specified otherwise
Origin
China
Contents
  1. Cable Type 600V
  2. Standards
  3. Cores & Size
  4. Application:
  5. Advantage of IEEE 1580 Cable

Cable Type 600V

Flame retardant:

TP (OBS)PN TP(OBS)PNA TP(OBS)PNB TP(OBS)PNBS

TP(OBS)LSEL TP(OBS)LSELA TP(OBS)LSELB TP(OBS)LSELBS

TP(OBS)PM TP(OBS)PMA TP(OBS)PMB TP(OBS)PMBS

Fire-resisting layer: FS Type only.

Cable Construction

Classification

Code

Construction details

Conductor

Annealed Stranded Copper Wire

Cable Type

TT

Signal Cable

Fire-resisting(Optional)

FS

Mica Tape

Insulation

P

Cross-Linked Polyolefin

LSE

Low Smoke EP Rubber

Overall Shied

OBS

Tinned copper wire braid

85% coverage over the cable core

Jacket

N

Flame Retardant Thermosetting Neoprene

L

Flame Retardant Low Smoke XLPO

M

Flame Retardant Mud Resistant XLPO

Armor(Optional)

B

Bronze

T

Tinned Copper Wire

Outer Sheath(Optional)

S

Same as Jacket

Standards

IEEE 1560(2001) IEC 45(1998)

UL 1309/CSA C 22.2 NO. 245(1995)

IEEE 1202(1991)

IEC 60332-3 Category A

CSA C 22.2 NO.38(at -40℃)

IEC 60331-1(FS type Cable)

NEK 606

Cores & Size

Cores: 1 2 4 5 7 10 12 14 16 19 24

Size (AWG or MCM): 18

Application:

The cable is fixed installation for signal, voltage up to 600V, apply for commercial marine, shipping building, MODU’S and Platform.

Advantage of IEEE 1580 Cable

Flame retardant

Fire-resistant (FS Type)

Resistance to oil, abrasion, petrochemical fluid, moisture and sunlight

Excellent flexibility

Mud Resistant