Back to product Download PDF
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet

IEEE Std 45/1580 Cable

600V TT(OS)PMBS Offshore Signal Cable(With Overall Shield)

Cable Type 600V Flame retardant:     TP (OS)PN TP(OS)PNA TP(OS)PNB TP(OS)PNBS     TP(OS)LSEL TP(OS)LSELA T...

ISO9001 Supplier Class Certificate Export Supply
600V TT(OS)PMBS Offshore Signal Cable(With Overall Shield)

Key Highlights

Category
IEEE Std 45/1580 Cable
Standard
DIN
Material
Tinned Copper/XLPE Insulation/ Neoprene/ Bronze/ Neoprene
Weight / Size
245(1995) IEEE 1202(1991) IEC 60332-3 Category A CSA C 22.2 NO.38(at -40...
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.

Technical Specifications

Category
IEEE Std 45/1580 Cable
Model / SKU
600V-TT-OS-PMBS-Offshore-Signal-Cable-With-Overall-Shield
Standard
DIN
Material
Tinned Copper/XLPE Insulation/ Neoprene/ Bronze/ Neoprene
Weight / Size
245(1995) IEEE 1202(1991) IEC 60332-3 Category A CSA C 22.2 NO.38(at -40℃) IEC 60331-1(FS type Cable) NEK 606   Cores & Size   Cores:
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
Warranty
12 Months unless specified otherwise
Origin
China
Contents
  1. Cable Type 600V
  2. Cable Construction
  3. Standards
  4. Cores & Size
  5. Application:
  6. Advantage of IEEE 1580 Cable

Cable Type 600V

Flame retardant:

TP (OS)PN TP(OS)PNA TP(OS)PNB TP(OS)PNBS

TP(OS)LSEL TP(OS)LSELA TP(OS)LSELB TP(OS)LSELBS

TP(OS)PM TP(OS)PMA TP(OS)PMB TP(OS)PMBS

TT (OS)PN TT (OS)PNA TT (OS)PNB TT (OS)PNBS

TT (OS)LSEL TT (OS)LSELA TT (OS)LSELB TT(OS)LSELBS

TT (OS)PM TT (OS)PMA TT (OS)PMB TT (OS)PMBS

Fire-resisting layer: FS Type only. TP: Pair twisted TT: Triple Twisted

Cable Construction

Classification

Code

Construction details

Conductor

Annealed Stranded Copper Wire

Cable Type

TT

Signal Cable

Fire-resisting(Optional)

FS

Mica Tape

Insulation

P

Cross-Linked Polyolefin

LSE

Low Smoke EP Rubber

Overall Shied

OS

AL/PS Overall tape with tinned copper wire

100% coverage over the cable core

Jacket

N

Flame Retardant Thermosetting Neoprene

L

Flame Retardant Low Smoke XLPO

M

Flame Retardant Mud Resistant XLPO

Armor(Optional)

B

Bronze

T

Tinned Copper Wire

Outer Sheath(Optional)

S

Same as Jacket

Standards

IEEE 1560(2001) IEC 45(1998)

UL 1309/CSA C 22.2 NO. 245(1995)

IEEE 1202(1991)

IEC 60332-3 Category A

CSA C 22.2 NO.38(at -40℃)

IEC 60331-1(FS type Cable)

NEK 606

Cores & Size

Cores: 3 4 5 7 10 12 14 16 19 24

Size (AWG or MCM):20 18 1614

Application:

The cable is fixed installation for signal, voltage up to 600V, apply for commercial marine, shipping building, MODU’S and Platform.

Advantage of IEEE 1580 Cable

Flame retardant

Fire-resistant (FS Type)

Resistance to oil, abrasion, petrochemical fluid, moisture and sunlight

Excellent flexibility

Mud Resistant