Back to product Download PDF
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet

JIS C 3410 Cable

FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V

JIS C 3410-1999 Marine Control and Signal Cable 250V MPYCY Cable is Multi Cores EP Rubber PVC Sheath Galvanized Steel Braided Cable with PVC CoveringCable 250V FA- MPYCY Cable is Multi Cores EP Rubber ...

ISO9001 Supplier Class Certificate Export Supply
FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V

Key Highlights

Category
JIS C 3410 Cable
Standard
JIS
Material
Tinned Copper/EPR insulation/PVC sheath/Galvanized Steel Wire Braided/PV...
Weight / Size
IEC 60332-1 & IEC 60332-3 Category A Cores & Size Number of Conductor:
Certificate
LR, ABS,BV, GL, RINA, DNV, NK, KR, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.

Technical Specifications

Category
JIS C 3410 Cable
Model / SKU
FA-MPYCY-Mutl-Cores-EP-Rubber-Marine-Control-and-Signal-Cable-250V
Standard
JIS
Material
Tinned Copper/EPR insulation/PVC sheath/Galvanized Steel Wire Braided/PVC Protective Covering
Weight / Size
IEC 60332-1 & IEC 60332-3 Category A Cores & Size Number of Conductor:
Surface
Galvanized
Certificate
LR, ABS,BV, GL, RINA, DNV, NK, KR, CCS
Warranty
12 Months unless specified otherwise
Origin
China
Contents
  1. China FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V:
  2. Cable Construction
  3. Standards
  4. Cores & Size
  5. Feature
  6. Maximum Working Voltage and Testing Voltage
  7. Minimum Bending Radius
  8. Application:

China FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V:

JIS C 3410-1999 Marine Control and Signal Cable

250V MPYCY Cable is Multi Cores EP Rubber PVC Sheath Galvanized Steel Braided Cable with PVC CoveringCable

250V FA- MPYCY Cable is Multi Cores EP Rubber PVC Sheath Galvanized Steel Braided Flame Retardant Cable with PVC Covering.

Cable Construction

Classification

Code

Construction details

Conductor

M

Tinned Copper Wire JIS C3410

Insulation

P

EPR as per JIS C 3410

Sheath

Y

PVC as per JIS C 3410

Armor

C

Galvanized steel wire braided

CB

Tinned copper wire braided

Paint

The white paint should be painted uniformly

Covering

Y

PVC as per JIS C 3410

Color: Black

Standards

Design : JIC C 3410(1999)

Flammability: IEC 60332-1 & IEC 60332-3 Category A

Cores & Size

Number of Conductor: 2 Cores, 4 Cores, 7 Cores, 12 Cores, 19 Cores, 27 Cores, 37 Cores, 44 Cores, 77 Cores.

Size of Conductor (mm2): 1 sqmm

Feature

Halogen-free, Low Smoke, Flame retardant

Maximum Working Voltage and Testing Voltage

Nominal voltage (V) Maximum working voltage (V) (Test voltage) V/min.
a.c d.c
250V 250V 450V 1500/5
0.6/1 kV 0.6/1 kV 0.9/1.5kV 3500/5

Minimum Bending Radius

The bending radius for the installation of cables should be not less than the values given as follows:

Type of cable Minimum bending radius
FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V

Up to 1.8/3kV Unarmored or unbraided
D ≤ 25mm 4XD
D > 25mm 6XD
Metal braid screened or armored 6XD
Tape screened 8XD
3.6/6kV Single core 12XD
above 3-core 9XD
NOTE) D : Overall diameter of cable
FA-MPYCY Mutl Cores EP Rubber Marine Control and Signal Cable 250V

Application:

The cable is fixed installation, used for Control, signal purpose in ship.