China FA-TTYCY-S Flame Retardant Marine Telephone and Instrument Cable 250V:
JIS C 3410-1999 Marine Telephone and Instrument Cable
250V TTYCY-S Cable is PVC Insulation Galvanized Steel Wire Braided and PVC Covering Cable with individual shield.
250V FA- TTYCY-S Cable is PVC Insulation Galvanized Steel Wire Braided and PVC Covering Flame Retardant Cable withindividual shield.
Cable Construction
Classification
Code
Construction details
Conductor
TT
Tinned Copper Wire JIS C3410
Insulation
Y
PVC as per JIS C 3410
Individual Shield
-S
Tinned Copper Wire
Armor
C
Galvanized steel wire braided
CB
Tinned copper wire braided
Paint
The white paint should be painted uniformly
Covering
Y
PVC as per JIS C 3410
Color: Black
Standards
Design : JIC C 3410(1999)
Flammability: IEC 60332-1 & IEC 60332-3 Category A
Cores & Size
Number of Conductor: 4P,7P, 10P, 14P, 19P, 24P, 30, 37P, 48P
Size of Conductor (mm2):1 sqmm
Feature
Halogen-free, Low Smoke, Flame retardant
Maximum Working Voltage and Testing Voltage
Nominal voltage (V) Maximum working voltage (V) (Test voltage) V/min. a.c d.c 250V 250V 450V 1500/5 0.6/1 kV 0.6/1 kV 0.9/1.5kV 3500/5
Minimum Bending Radius
The bending radius for the installation of cables should be not less than the values given as follows:
Type of cable Minimum bending radius Up to 1.8/3kV Unarmored or unbraided D ≤ 25mm 4XD D > 25mm 6XD Metal braid screened or armored 6XD Tape screened 8XD 3.6/6kV Single core 12XD above 3-core 9XD
NOTE) D : Overall diameter of cable
Application:
The cable is fixed installation, used for Telephone and Instrument purpose in ship.