Back to product Download PDF
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet

JIS C 3410 Cable

FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V

JIS C 3410-1999 Marine Telephone and Instrument Cable 250V TTYCYS Cable is PVC Insulation Galvanized Steel Wire Braided and PVC Protective Covering Cable with Common Shield. 250V FA- TTYCYS Cabl...

ISO9001 Supplier Class Certificate Export Supply
FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V

Key Highlights

Category
JIS C 3410 Cable
Standard
JIS
Material
Tinned Copper/PVC insulation/Common Shield/Galvanized Steel Wire Braided...
Weight / Size
IEC 60332-1 & IEC 60332-3 Category A Cores & Size Number of Conductor:
Certificate
LR, ABS,BV, GL, RINA, DNV, NK, KR, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.

Technical Specifications

Category
JIS C 3410 Cable
Model / SKU
FA-TTYCYS-Flame-Retardant-Marine-Telephone-and-Instrument-Cable-250V
Standard
JIS
Material
Tinned Copper/PVC insulation/Common Shield/Galvanized Steel Wire Braided/PVC Protective Covering
Weight / Size
IEC 60332-1 & IEC 60332-3 Category A Cores & Size Number of Conductor:
Surface
Galvanized
Certificate
LR, ABS,BV, GL, RINA, DNV, NK, KR, CCS
Warranty
12 Months unless specified otherwise
Origin
China
Contents
  1. China FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V:
  2. Cable Construction
  3. Standards
  4. Cores & Size
  5. Feature
  6. Maximum Working Voltage and Testing Voltage
  7. Minimum Bending Radius
  8. Application:

China FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V:

JIS C 3410-1999 Marine Telephone and Instrument Cable

250V TTYCYS Cable is PVC Insulation Galvanized Steel Wire Braided and PVC Protective Covering Cable with Common Shield.

250V FA- TTYCYS Cable is PVC Insulation Galvanized Steel Wire Braided and PVC Protective Covering Flame Retardant Cable with Common Shield.

Cable Construction

Classification

Code

Construction details

Conductor

TT

Tinned Copper Wire JIS C3410

Insulation

Y

PVC as per JIS C 3410

Common Shield

S

Tinned Copper Wire

Armor

C

Galvanized steel wire braided

CB

Tinned copper wire braided

Paint

The white paint should be painted uniformly

Covering

Y

PVC as per JIS C 3410

Color: Black

Standards

Design : JIC C 3410(1999)

Flammability: IEC 60332-1 & IEC 60332-3 Category A

Cores & Size

Number of Conductor: 1P, 1T, 1Q, 4P,7P, 10P, 14P, 19P, 24P, 30, 37P, 48P

Size of Conductor (mm2):1 sqmm

Feature

Halogen-free, Low Smoke, Flame retardant

Maximum Working Voltage and Testing Voltage

Nominal voltage (V) Maximum working voltage (V) (Test voltage) V/min.
a.c d.c
250V 250V 450V 1500/5
0.6/1 kV 0.6/1 kV 0.9/1.5kV 3500/5

Minimum Bending Radius

The bending radius for the installation of cables should be not less than the values given as follows:

Type of cable Minimum bending radius
FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V

Up to 1.8/3kV Unarmored or unbraided
D ≤ 25mm 4XD
D > 25mm 6XD
Metal braid screened or armored 6XD
Tape screened 8XD
3.6/6kV Single core 12XD
above 3-core 9XD
NOTE) D : Overall diameter of cable

FA-TTYCYS Flame Retardant Marine Telephone and Instrument Cable 250V

Application:

The cable is fixed installation, used for Telephone and Instrument purpose in ship.