1, heat transfer is the best cooling effect more than the cooler adopts tubular, cooling area is large, cooling effect is better.
2, cooling area The brass number used by the cooler for fin tube and roll tooth shape tube more than 3 times, cooling area according to the brass surface area calculation, help cooling area.
3 the optimal cooling, cooling pipe materials Using pure copper tube heat transfer rate is more than 0.95.
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet
Heat Exchanger
OR series multi tube cooler
The OR cooler key features: 1, heat transfer is the best cooling effect more than the cooler adopts tubular, cooling area is large, cooling effect is better. 2, cooling area The brass number used by the cooler for...
ISO9001 Supplier
Class Certificate
Export Supply
Key Highlights
Category
Heat Exchanger
Standard
DIN
Material
3 the optimal cooling, cooling pipe materials Using pure copper tube hea...
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.
Technical Specifications
Category
Heat Exchanger
Model / SKU
OR-series-multi-tube-cooler
Standard
DIN
Material
3 the optimal cooling, cooling pipe materials Using pure copper tube heat transfer rate is more than 0.95.
Surface
2, cooling area The brass number used by the cooler for fin tube and roll tooth shape tube more than 3 times, cooling area according to the brass surface area calculation, help cooling area.
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
Warranty
12 Months unless specified otherwise
Origin
China
The OR cooler key features:
OR cooler note:
1, the product is only suitable for fresh water.
2, oil lateral pressure is 1.0 Mpa;Use water side pressure is 0.5 Mpa.
3, the freezing season, may occur in cooling water should be out of the water in the cooler when not working.
4, radiator pipe cleaning every six months (copper tube diameter) in order to keep a good cooling effect.
2, oil lateral pressure is 1.0 Mpa;Use water side pressure is 0.5 Mpa.
3, the freezing season, may occur in cooling water should be out of the water in the cooler when not working.
4, radiator pipe cleaning every six months (copper tube diameter) in order to keep a good cooling effect.
Technical data:
| Model | A | B | C | R | D | G | F | Flow |
| OR-60 | 450 | 305 | 45 | 89 | 125 | 3/4 | 3/4 | 60 |
| OR-100 | 555 | 403 | 68 | 114 | 145 | 3/4 | 3/4 | 100 |
| OR-150 | 575 | 385 | 85 | 140 | 175 | 11/4 | 1 | 150 |
| OR-250 | 780 | 585 | 85 | 140 | 175 | 11/4 | 1 | 250 |
| OR-350 | 1180 | 990 | 85 | 140 | 175 | 11/4 | 1 | 350 |
| OR-600 | 1175 | 950 | 90 | 165 | 200 | 2 | 11/4 | 600 |
| OR-800 | 1700 | 1490 | 90 | 165 | 200 | 2 | 11/4 | 800 |
| OR-1000 | 2140 | 1890 | 90 | 165 | 200 | 2 | 11/4 | 1000 |
| OR-1200 | 2530 | 2270 | 90 | 165 | 200 | 2 | 11/4 | 1200 |