Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet
Sewage Treatment Plant
WCMBR-50(U) Type Sewage Treatment Plant
Description: WCMBR-X(U) Type Sewage Treatment Plant adopts the principle of sequence-membrane to treat the pollutant. Sewage first enters into the buffer tank to adopt the biochemical treatment. Meantime the tank c...
ISO9001 Supplier
Class Certificate
Export Supply
Key Highlights
Category
Sewage Treatment Plant
Standard
DIN
Weight / Size
AC440V/50HZ Power (kw) 5 5 5 5 5 5 6 10 10 10 11 12 14 14 Outline dimens...
Certificate
CCS GL BV ABS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.
Technical Specifications
Category
Sewage Treatment Plant
Model / SKU
WCMBR-50-U-Type-Sewage-Treatment-Plant
Standard
DIN
Weight / Size
AC440V/50HZ Power (kw) 5 5 5 5 5 5 6 10 10 10 11 12 14 14 Outline dimension 1750x 1400x 1600 2000x 1400x 1600 2000x 1600x 1700 2100 x1900 x1750 2100 x1900 x1850 2450x 1900x 1750 2600x 2100x 2035 2900x 2100x 2050 3000x 2300x 2100 3500x 2300x 2100 3650x 2950x 2300 3850x 3250x 2164 5000x 2900x 2450 5500x 3200x 2460 Dry weight(kg) 1200 1250 1420 1800 2000 2100 2550 3800 4350 4800 5000 6500 6950 7500 Wet weight(kg) 2000 2600 3370 4000 5100 5700 7500 9540 11000 12900 16200 19600 22500 27150 Effluent quality TTS≤35mg/l,BOD5≤25mg/l,COD≤125mg/l,Thermotolerant coliform≤100/100mg, PH6-8.5, Resdual Chlorine Cl2<0.5mg/l
Certificate
CCS GL BV ABS
Warranty
12 Months unless specified otherwise
Origin
China
Description:
WCMBR-X(U) Type Sewage Treatment Plant adopts the principle of sequence-membrane to treat the pollutant. Sewage first enters into the buffer tank to adopt the biochemical treatment. Meantime the tank can contain the sewage peak load. When the liquid in the tank reaches the starting-level, the sewage is transferred into the sequence tank with soft stuffing, and treated with the way of sequence biological contacted oxidization treatment. Then the treated sewage is transferred into the clean water tank. When the liquid reaches the certain level, the clean water is transferred into the membrane assembly or discharged directly. The permeated effluent should be discharged to overboard after ozone disinfection or UV disinfection. The quality of the effluent meets with the requirements of IMO MEPC159( 55) resolution. For this product, we have gained CCS type approval certificate, IMO certificate, USCG、ABS and EC certificate.
Character:
1 adopts sidestream membrane for more convenient change and maintenance;
2 adopts various measures to prolong thse service life of the membrane;
3 adopts the buffer tank and dormancy to meet with the requirement of peak load;
4 adopts the ozone disinfection or UV disinfection, avoids secondary pollution, decolors well;
5 adopts the PLC controlling procedure for more convenient operation and maintenance;
6 adopts sequencing batch reactors (SBR), the rate of sludge loading is high, the treatment is more ef-fective, the quality of discharged sludge is less;
7 sets the automatic dormancy procedure to be acceptable the condition of zero loading sewage;
8 sets various treatment manners to meet with the requirements of diferent sea areas;
9 The plant can be used for treating vacuum collected condense sewage, for hydraulic load is small, membrane is even more applicable.
2 adopts various measures to prolong thse service life of the membrane;
3 adopts the buffer tank and dormancy to meet with the requirement of peak load;
4 adopts the ozone disinfection or UV disinfection, avoids secondary pollution, decolors well;
5 adopts the PLC controlling procedure for more convenient operation and maintenance;
6 adopts sequencing batch reactors (SBR), the rate of sludge loading is high, the treatment is more ef-fective, the quality of discharged sludge is less;
7 sets the automatic dormancy procedure to be acceptable the condition of zero loading sewage;
8 sets various treatment manners to meet with the requirements of diferent sea areas;
9 The plant can be used for treating vacuum collected condense sewage, for hydraulic load is small, membrane is even more applicable.
Technical data:
| Type | WCMBR- | |||||||||||||
| 10(U) | 20(U) | 30(U) | 40(U) | 50(U) | 60(U) | 80(U) | 100(U) | 120(U) | 150(U) | 200(U) | 250(U) | 300(U) | 400(U) | |
| Rated persons | 10 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | 120 | 150 | 200 | 250 | 300 | 400 |
| Hydraulic Load | 0.84 | 1.54 | 2.31 | 3.08 | 3.78 | 4.48 | 6.02 | 7.7 | 9.1 | 11.2 | 14.7 | 18.2 | 23.1 | 30.8 |
| Organic Load | 0.42 | 0.77 | 1.155 | 1.54 | 1.89 | 2.24 | 3.01 | 3.85 | 4.55 | 5.6 | 7.35 | 9.1 | 11.55 | 15.4 |
| Power | AC380V/50HZ. AC415V/50V. AC440V/50HZ | |||||||||||||
| Power (kw) | 5 | 5 | 5 | 5 | 5 | 5 | 6 | 10 | 10 | 10 | 11 | 12 | 14 | 14 |
| Outline dimension | 1750x 1400x 1600 | 2000x 1400x 1600 | 2000x 1600x 1700 | 2100 x1900 x1750 | 2100 x1900 x1850 | 2450x 1900x 1750 | 2600x 2100x 2035 | 2900x 2100x 2050 | 3000x 2300x 2100 | 3500x 2300x 2100 | 3650x 2950x 2300 | 3850x 3250x 2164 | 5000x 2900x 2450 | 5500x 3200x 2460 |
| Dry weight(kg) | 1200 | 1250 | 1420 | 1800 | 2000 | 2100 | 2550 | 3800 | 4350 | 4800 | 5000 | 6500 | 6950 | 7500 |
| Wet weight(kg) | 2000 | 2600 | 3370 | 4000 | 5100 | 5700 | 7500 | 9540 | 11000 | 12900 | 16200 | 19600 | 22500 | 27150 |
| Effluent quality | TTS≤35mg/l,BOD5≤25mg/l,COD≤125mg/l,Thermotolerant coliform≤100/100mg, PH6-8.5, Resdual Chlorine Cl2<0.5mg/l | |||||||||||||