YCTJ-H Series Fan-Closed Three Phase Induction Marine Motor
Introduction
YCTJ-H series three phase induction motor can be totally enclosed.fan-closed three phase induction motor that can be used on marine .civil cooperating with marine .this series work as power supply for...
ISO9001 SupplierClass CertificateExport Supply
Key Highlights
Category
Marine Electric Motor
Standard
DIN
Weight / Size
Type designation Operating Conditions Temperature of Ambient air 0℃ ~45℃...
Certificate
CCS/LR/DNV/KR
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.
Type designation Operating Conditions Temperature of Ambient air 0℃ ~45℃ Altitude 0M Relative humidity ≤ 95% Dew exists Oil mist exists Fungus exists Shock exists Vibration exists Inclination and swing ±22.5° Rated voltage and frequency 50HZ.380V or 60HZ.440V Connection Δ(Y) Duty type continuous (S1)or S2-30 type Insulation B or F Temperature rise of winding 75K or 100K Permissible working temperature of bearing 90℃ (thermometer method) Type of starting Direct on full-voltage starting for all sizes;
Surface
5/86 740 680 800 750 680 1035 1675 355L 1675 400M FF940 90/110 210 22/28 81/100 940 880 1000 28 980 920 1010 1720 annotate: a) R is distance from fitting surface of flange to shaft shoulder.
Certificate
CCS/LR/DNV/KR
Warranty
12 Months unless specified otherwise
Origin
China
Introduction
YCTJ-H series three phase induction motor can be totally enclosed.fan-closed three phase induction motor that can be used on marine .civil cooperating with marine .this series work as power supply for warship. motor for side thruster radiator .This series has low strat current and high start torque,Every performance is better than any other motors which has same specification.The motors are completely according with the requirement of the following standards and specifications.
Type designation
Operating Conditions
Temperature of Ambient air 0℃ ~45℃
Altitude 0M
Relative humidity ≤ 95%
Dew exists
Oil mist exists
Fungus exists
Shock exists
Vibration exists
Inclination and swing ±22.5°
Rated voltage and frequency 50HZ.380V or 60HZ.440V
Connection Δ(Y)
Duty type continuous (S1)or S2-30 type
Insulation B or F
Temperature rise of winding 75K or 100K
Permissible working temperature of bearing 90℃
(thermometer method)
Type of starting Direct on full-voltage starting for all sizes; reduced voltage starting allowable at no load .
Vibration and Noise
The effective values of vibration velocity, measured at the no-load conditions, does not exceed those given in table 1.
table 1
Frame Size
The effective values of vibration velocity mm/s
160~225
2.8
250~355
3.5
400 and above
4.5
The following table 2 is showed about the noise condition when the motor is no-load
table 2
output kW
Synchronous speed r/min
3600
3000
1500、 1800
1000、 1200
750、 900
600、 720
sound power level dB (A)
4
—
—
—
—
69
—
5.5
69
7.5
75
72
11
87
87
82
75
72
15
87
87
82
78
75
18.5
87
87
82
78
75
22
92
92
82
78
78
30
95
95
84
81
78
37
95
95
84
81
78
45
97
97
84
84
78
87
55
97
97
86
84
81
87
75
99
99
92
90
87
87
90
99
99
92
90
87
92
110
104
104
98
92
87
92
132
105
104
101
92
99
92
160
105
104
101
102
99
97
200
105
104
101
102
99
97
250
113
111
108
105
101
99
315
113
111
108
108
105
101
355
115
113
111
111
105
101
400
115
113
111
111
108
—
450
116
113
111
111
—
500
118
116
115
—
560
118
116
115
Technical Data
The protection of the frame size and the output are IP23 should cooperate with the table3,And the IP44 is cooperate with table4.
table3
frame size
number of poles
2
4
6
8
10
power kW
160M
15
11
7.5
5.5
—
160L1
18.5
15
11
7. 5
160L2
22
18.5
—
—
180M
30
22
15
11
180L
37
30
18.5
15
200M
45
37
22
18.5
200L
55
45
30
22
225S
75
55
37
30
225M
90
75
45
37
250M
110
90
55
45
280S
—
110
75
55
280M
132
132
90
75
315S
160
160
110
90
55
315M
200
200
132
110
75
315L
250
250
160
132
90
355M
315
315
200
160
110
355L
355
355
250
200
132
400M1
400
400
315
250
160
400M2
450
450
355
200
400L1
500
500
400
315
250
400L2
560
560
450
355
315
table4.
Frame Size
Number of poles
2
4
6
8
10
output kW
160M1
11
11
7.5
4
—
160M2
15
5.5
160L
18.5
15
11
7.5
180M
22
18.5
—
—
180L
—
22
15
11
200L1
30
30
18.5
15
200L2
37
22
225S
—
37
—
18.5
225M
45
45
30
22
250M
55
55
37
30
280S
75
75
45
37
280M
90
90
55
45
315S
110
110
75
55
45
315M
132
132
90
75
55
315L1
160
160
110
90
75
315L2
200
200
132
110
90
355M1
250
250
160
132
110
355M2
200
160
132
355L
315
315
250
200
160
400M1
355
355
280
220
200
400M2
400
400
315
250
400M3
450
450
—
—
The mounting of this series is IMV1,mounting and overall dimension for motors of various mounting
arrangements are shown respectively by figure below and table 5 ~6.
Table 5 The Motors that end shield existing flange but the frame without foot(IP23) unit:mm
Frame Size
Flange size
Mounting dimension and tolerance
Overall dimension
D
E
F
G
M
N
P
R
S
T
n
AC
AD
HF
L
160M
FF300
42
110
12
37
300
250
350
0
19
ф1.5 M
5.0
4
325
270
450
660
160L
705
180M
48
14
42.5
360
290
490
730
180L
765
200L
FF350
55
16
49
350
300
400
400
355
550
840
225S
FF400
55/60
110/140
18
49/53
400
350
450
8
450
370
610
890
225M
865/915
250M
FF500
60/65
140
53/58
500
450
550
495
455
640
995
280S
65/75
18/20
58/67. 5
550
470
720
1090
280M
1140
315S
FF600
65/80
170
18/22
58/71
600
550
660
24
ф2.0 M
6.0
645
576
900
1390
315M
1490
315L
1490
355M
FF740
75/95
22/25
67. 5/86
740
680
800
750
680
1035
1675
355L
1675
400M
FF940
90/110
210
22/28
81/100
940
880
1000
28
980
920
1010
1720
annotate: a) R is distance from fitting surface of flange to shaft shoulder. b) Numerator is a data of two poles, Denominator is a data of more than four poles.
Table 6 The Motors that end shield existing flange but the frame without foot(IP44) unit:mm
Frame Size
Flange size
Mounting dimension and tolerance
Overall dimension
D
E
F
G
M
N
P
R
S
T
n
AC
AD
HF
L
160M
FF300
42
110
12
37
300
250
350
0
19
ф1.5 M
5.0
4
325
270
450
660
160L
705
180M
48
14
42.5
360
290
490
730
180L
765
200L
FF350
55
16
49
350
300
400
400
355
550
840
225S
FF400
55/60
110/140
18
49/53
400
350
450
8
450
370
610
890
225M
865/915
250M
FF500
60/65
140
53/58
500
450
550
495
455
640
995
280S
65/75
18/20
58/67. 5
550
470
720
1090
280M
1140
315S
FF600
65/80
170
18/22
58/71
600
550
660
24
ф2.0 M
6.0
645
576
900
1390
315M
1490
315L
1490
355M
FF740
75/95
22/25
67. 5/86
740
680
800
750
680
1035
1675
355L
1675
400M
FF940
90/110
210
22/28
81/100
940
880
1000
28
980
920
1010
1720
annotate: a) R is distance from fitting surface of flange to shaft shoulder. b) Numerator is a data of two poles, Denominator is a data of more than four poles.