Back to product Download PDF
Jinbo Marine
Marine & Offshore Equipment Datasheet
Product Datasheet

Combustible Gas Alarm System

GTQ-GN8020 Portable Combustinle To Xic Gas Detector

GTQ-GN8020 Portable Combustinle To Xic Gas Detector 1)Chapters 1 and 2, Part Four of China Classification Society Rules for Classification of Sea-going Steel Ships 2)Chapter 3, Part Six of China Classification Soc...

ISO9001 Supplier Class Certificate Export Supply
GTQ-GN8020 Portable Combustinle To Xic Gas Detector

Key Highlights

Category
Combustible Gas Alarm System
Standard
DIN
Material
GTQ-GN8020 Portable Combustinle To Xic Gas Detector 1)Chapters 1 and 2, ...
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
We can supply according to your requirement, drawings, class certificate needs, and delivery schedule.

Technical Specifications

Category
Combustible Gas Alarm System
Model / SKU
GTQ-GN8020-Portable-Combustinle-To-Xic-Gas-Detector
Standard
DIN
Material
GTQ-GN8020 Portable Combustinle To Xic Gas Detector 1)Chapters 1 and 2, Part Four of China Classification Society Rules for Classification of Sea-going Steel Ships 2)Chapter 3, Part Six of China Classification Society Rules for Classification of Sea-going Steel Ships 3)Regulations 4, Chapter II-2 of International Convention for the Safety of Life at Sea, 1974, as Amended 4) GB 16808-2008 Combustible Gas Alarm Control Units 5) IEC 60079-29-1:2016+AMD1:2020 Explosive atmospheres -Part 29-1:
Certificate
ABS, LR, BV, DNVGL, NK, KR, IRS, RMRS, CCS
Warranty
12 Months unless specified otherwise
Origin
China

China GTQ-GN8020 Portable Combustinle To Xic Gas Detector:

GTQ-GN8020 Portable Combustinle To Xic Gas Detector

1)Chapters 1 and 2, Part Four of China Classification Society Rules for Classification of Sea-going Steel Ships
2)Chapter 3, Part Six of China Classification Society Rules for Classification of Sea-going Steel Ships
3)Regulations 4, Chapter II-2 of International Convention for the Safety of Life at Sea, 1974, as Amended
4) GB 16808-2008 Combustible Gas Alarm Control Units
5) IEC 60079-29-1:2016+AMD1:2020 Explosive atmospheres -Part 29-1: Gas detectors -Performance requirements of detectors for flammable gases

Detection of gases HC(Hydrocarbon) Transfer method The maximum 4500m
(RvvP3*2.5mm²
Copper core cable)
Detection principle Catalytic combustion Operating method Magnetic pen
Detection range 0~100%LEL Alarm setting Two section Alarm
(default 20%LEL,Adjustable
as range required)
Precision ±3%FS Shell material Aluminum alloy/stainless steel
Corresponding time ≤30Seconds Explosion-proof signs ExdbIICT6 Gb
Recovery time ≤30Seconds IP rating ip66
Power
consumption: 2.5w
Operating temperature -20°℃~50°℃
Output singal 4~20m Standard
current(3lines)
Relative humidity 0~95%RH(Non-condensation)